Genrating Sets

Power Genset / Welding Sets

AGRO / FARM MACHINERY

IRRIGATION / DEWATERING

POWER GENSET WELDING SETS

AGRO ENGINE / PRIME MOVER

Spare Parts

Diesel Generators Three Phase

ENGINE
Cooling Water /Air
No. of Cyl. One / Two
Fuel H.S. Diesel
Speed 1500 RPM
SFC 1 gms/HP-Hr
A. C. GENERATOR
Voltage 230/415 V
Phase Single/Three
Frequency 50 Hz
Regulation ± 5 % Max.
Insulation F Class
Mounting Foot
MODEL KVA KW BHP RPM No. Of Piston Cooling Packing Size (cm) Nett. Wt. Kg. Gross Wt. Kg.
SINGLE PHASE 240 Volts 50 Hz
MINI 2 2 4.5 1500 SINGLE Water/Air 90x50x100 125 170
V-2 4 4 6.5 1500 SINGLE Water/Air 112x65x130 325 475
V-3 5 5 8 1500 SINGLE Water/Air 112x65x130 330 485
V-4 6 6 10 1500 SINGLE Water/Air 112x65x130 360 510
V-5 7 7 11 1500 SINGLE Water/Air 112x65x135 370 520
V-6 8 8 14 1500 SINGLE Water 112x65x135 390 540
V-7 10 10 15 1500 DOUBLE Water/Air 120x70x160 445 64
V-8 12 12 20 1500 DOUBLE Water/Air 120x70x160 450 645
V-9 14 14 22 1500 DOUBLE Water/Air 120x70x160 460 655
V-10 16 16 18 1500 DOUBLE Water 125x85x165 470 665
V-10H 18 18 30 1500 DOUBLE Water 125x85x165 490 690
MODEL KVA KW BHP RPM No. Of Piston Cooling Packing Size (cm) Nett. Wt. Kg. Gross Wt. Kg.
THREE PHASE 415 Volts 4 pole 50 Hz
V-11 6.25 5 8 1500 SINGLE Water/Air 112x65x130 340 490
V-12 7.5 6 10 1500 SINGLE Water/Air 112x65x130 365 515
V-13 8.75 7 11 1500 SINGLE Water/Air 112x65x135 380 530
V-14 10 8 14 1500 SINGLE Water 120x70x160 400 550
V-15 10 8 15 1500 DOUBLE Water/Air 120x70x160 450 640
V-16 12.5 10 15 1500 DOUBLE Water/Air 120x70x160 456 645
V-17 15 12 20 1500 DOUBLE Water/Air 120x70x160 485 670
V-18 17.5 14 22 1500 DOUBLE Water/Air 120x70x160 495 690
V-19 20 16 28 1500 DOUBLE Water 125x85x165 510 710
V-19H 22 18 30 1500 DOUBLE Water 125x85x165 130 740

BRIEF SPECIFICATIONS

GOVERNING
A sensible mechnanical centrifugal type governer mounted on the camshaft gear. Speed variation is controlledwithin limits to comply with class B1 governing as per IS:10001 (GENERAL PURPOSE).

COOLING
Engine is continuously cooled by flow of water. Either by Radiator mounted on engine or direct water supply. Front radiator mounted engines also available.

STARTING
The engine is designed for starting by hand. Electric Start Provision can also be provided against specific reauirement. Dynamo battery chargers also available

POLLUTION CONTROL DEVICE
Single Element Catalytic Converter for control of NOx, CO, THC & HAPs.

SOUND & VIBRATION CONTROL DEVICE
We offer Canopy, Industrial type Air cleaner & Silencer, Round Duct Expansion Joints, Anti Vibration Mounts etc.

ENGINE SAFTY DEVICE (OPTIONAL)
Engine controller with Manual Start/ Stop, Automatic shut down for fault, Keyswitch operation, 16A contacts for start/stop, Electronic warning lamp.

ENGINE SAFTY DEVICE CONTROLLER (OPTIONAL)
Display of Battery Voltage, Oil Pressure, Temperature, Engine RPM & Running Hrs. , 14 Programmable parameters, Electronic alternator excitation circuit, 5 Digital & 4 Analog inputs, 3 relay outputs for start, Stop and one is programmable, Engine run hours counter, Automatic & manual operation mode, Remote Start & stop function. Sound Proofing canopy can also supplied.

DIESEL WATER COOLED GENSET

ENGINE
Cooling Water Cooled
Fuel H.S. Diesel
Speed 1500 RPM
Type Vertical ,4-stroke,compression ignition
Injection Direct by multi-hole nozzel
RPM 1500-1800
Starting Electrical (12 Volts)
Governor Mechanical
A. C. GENERATOR
Voltage 230/415 V
Phase Single/Three
Frequency 50 Hz
Insulation F Class
Power Factor 0.8
  AC GENERATORS       DIESEL ENGINE
MODEL RATED OUTPUT CURRENT (AMPS) RATED
POWER
(HP)
NO. OF
CYLINDERS
SWEPT
VOLUME
(CC)
SPE. FUEL
CONSUMP TION
(GM/BHP-HR)
aspirator TION
KVA KW THREEPHASE SINGLEPHASE
VMG 25 25 20 35 105 32 2 2376 162 Natural
VMG 30 30 24 42 126 41 3 3307 162 Natural
VMG 35 35 28 49 147 46* 3 3307 162 Natural
VMG 40 40 32 56 168 56 4 4561 159 Natural
VMG 45 45 36 63 189 56 4 4561 159 Natural
VMG 50 50 40 70 210 62* 4 4561 169 Natural
VMG 65 65 52 90 NA 84 4 4561 162 Turbo Charged
VMG 82 82.5 66 114 NA 106 6 6614 152 Turbo Charged
VMG 100 100 80 138 NA 125 6 6614 152 Turbo Charged

STANDARD SPECIFICATIONS

GENERATING SETS
These are used in various fields as emergency power supplies, autonomous power supplies or for industrial uses. All of our generating sets are designed to comply with the current regulations to ensure that the operators have the security of a high level of quality. The predominant factors during development is security of operation, which allows our customers to operate in absolute safety. The components that are used for the construction of our machines are the result of precise selection of our suppliers, which gives us high standards of quality at low costs of production. First class materials and superior quality finishing are reliability characterize our products. They respective range of power and are chosen on the basis of their innovative specifications by many important users in industry, agriculture, building and hire.

EMERGENCY POWER SUPPLY
For use during an interruption of the mains power supply, where the absence of electricity would cause serious problems.

MAIN USERS
Hospitals, places of public performance, where the environment is at risk, private house hold and industry.

These are characterized by high performance, low fuel consumption and low maintenance. Engines are Petter Type, Water or Air Cooled, Single/Double/Three Cylinder and superior quality. Our engines are ISI Marked which is the highest quality mark in India and it is also equivalent to British standards. Latest generation air or water cooled, 1500rpm,electric or handle start, long durability and high reliability.

COOLING SYSTEMS

AIR COOLED
Air cooled are of two types.

FAN TYPE
The fan is mounted on the flywheel side. Air circulates through cowling towards the cylinder and cylinder head.

BLOWER TYPE
A blower mounted towards the gear cover is driven by V-belt and powered by the CAM Gear for forced cooling of the cylinder block and head.

WATER COOLED
Radiator Type.

STARTING SYSTEMS

MANUAL START
Handle is used to crank the engine.

ELECTRIC START
12 Volt Battery operated starting system.

AMF
Auto Mains Failure. The Genset starts within 7 – 10 seconds on the mains failure and Genset stops automatically within 7 seconds of the resumption of main power.

ALTERNATOR

We use self-exciting, self regulating, alternating current with superior capacity for peak during the starting of electric motors and constructed according to the ISI Standards. The great versatility of these alternators make it possible to built versions with different voltages and frequencies. Mechanical construction is with frames in steel. Cooling is by aluminum FAN shrunk on the shaft, rotor has steel laminations with damping cage, insulation type H , impregnation with epoxy varnish, tropicalised.

PRIVATE ARMATURE
Core of high quality silicon Steel Stampings for minimum energy losses. Core is rigidly keyed to a sturdy shaft and clamped with heavy end-rings.

PRIVATE WINDING AND INSULATION
Both D.C. and A.C. Windings are made of highly conductive super- synthetics enameled copper wire manufactured by top leading Companies in India. With highly varnished and dried field coils and armature windings is of class E insulation.

PRIVATE VARNISHING AND BAKING
All windings are properly varnished in vacuum impregnation machine, backed for suitable time and at fixed temperature in special designed Oven.

PRIVATE DYNAMIC BALANCING
all fittings Rotor is dynamically balanced in a semi computerized dynamic balancing machine.

MOUNTNG SYSTEM

MOUNTINGS ARE STURDY CHANNELED BASE PLATES WITH ANY OF THE BELOW
Anti-vibration padding or Trolley wheels

CONTROL PANEL

(FABRICATED FROM SHEET STEEL)

  • Panel “Standard” Voltmeter, Ammeter, Changeover Switches, Selector switches, HRC switches ,MCB ,Charger
  • Panel “Super” AMF, Voltmeter, Ammeter, Changeover Switches, Selector switches, HRC switches ,MCB ,Time Totalizer, Lub. Oil Pressure Gauge, Water Temp. Gauge ,Charger.

Spare Parts

Click to See